Surfix Pro X Gauge |
||
1 |
Gauge |
Supports multiple probes |
|
|
Automatically identifies substrate type and activates appropriate measuring procedure |
|
|
Scan mode enables continuous measurement |
|
|
Automatic identification of probe type used |
|
|
Supports units m and mils |
2 |
Memory |
Large data memory for 100,000 readings, 1,000 selectable files, Free choice of filename |
|
|
Saved readings and statistical values individually recallable |
3 |
Data Output |
Data transfer via USB 2.0 und Bluetooth 4.0 |
4 |
Statistics |
Single and block value, selectable block size |
5 |
Calibration |
Factory, Zeroing (1-point calibration), |
6 |
Protection class |
Protection class - IP 52 (proof against dust and dripping water) |
7 |
Display |
High resolution Color display Backlight, 4-digit alphanumeric |
8 |
Standards |
DIN, ISO, ASTM, BS |
9 |
Measuring Principle |
Magnetic induction principle (F-Mode) Eddy-current principle (N-Mode) |
10 |
Limit values |
Freely selectable; optical and acoustic signal if limit value is exceeded |
Probe FN 1.5/ (For measurement OD) |
||
Range |
0 - 1,500 m |
|
Substrate |
Ferrous (F & FN Model) Non-Ferrous (FN & N Model) |
|
Tolerance |
(1 m + 1 % of reading) |
|
Resolution |
0.1 m or < 0.2 % of reading |
|
Min. Area of measurement |
5 mm x 5 mm |
|
Minimum radius of curvature |
Convex 1.5 mm, Concave 20 mm |
|
Minimum substrate thickness |
Iron/Steel: 0.2 mm (F & FN Model) Non-Ferrous 50 microns (N & FN Model) |
|
Surface Temperature |
-15 C to 60 C |
F 1.5 (For measurement OD) |
||
Range |
0 - 1,500 m |
|
Substrate |
Ferrous |
|
Tolerance |
(1 m + 1 % of reading) |
|
Resolution |
0.1 m or < 0.2 % of reading |
|
Min. Area of measurement |
5 mm x 5 mm |
|
Minimum radius of curvature |
Convex 1.5 mm, Concave 20 mm |
|
Minimum substrate thickness |
Iron/Steel: 0.2 mm |
|
Surface Temperature |
-15 C to 60 C |
N 1.5 (For measurement OD) |
||
Range |
0 - 1,500 m |
|
Substrate |
Non-Ferrous |
|
Tolerance |
(1 m + 1 % of reading) |
|
Resolution |
0.1 m or < 0.2 % of reading |
|
Min. Area of measurement |
5 mm x 5 mm |
|
Minimum radius of curvature |
Convex 1.5 mm, Concave 20 mm |
|
Minimum substrate thickness |
Non-Ferrous 50 microns |
|
Surface Temperature |
-15 C to 60 C |
Probe FN 1.5/90 (SPECIAL PROBE FOR ID MEASUREMENT) |
||
Range |
0 1,500 m for Iron/Steel |
|
Substrate |
Ferrous and Non-Ferrous |
|
Tolerance |
(1 m + 1 % of reading) |
|
Resolution |
0.1 m or < 0.2 % of reading |
|
Min. Area of measurement |
5 mm x 5 mm |
|
Minimum radius of curvature |
Convex 1.5 mm, Concave 6 mm |
|
Minimum thickness of substrate |
Iron/Steel: 0.2 mm |
|
Surface Temperature |
-15 C to 60 C |
|
Min ID for measurement |
13 mm |
Probe FN 3.5 (For measurement OD) |
||
Range |
0 - 3,500 m for Ferrous substrates 0 - 3,-00 m for Non-Ferrous substrates |
|
Substrate |
Ferrous and Non-Ferrous |
|
Tolerance |
(2 m + 2 % of reading) |
|
Resolution |
0 1,000 m: 1 m 1,000 2,500 m: 2 m 2,500 3,500 m: 5 m |
|
Min. Area of measurement |
10 mm x 10 mm |
|
Minimum radius of curvature |
Convex 5 mm, Concave 50 mm |
|
Minimum substrate thickness |
Iron/Steel: 0.5 mm Non-Ferrous 50 microns |
|
Surface Temperature |
-15 C to 60 C |